Server RAM upgrade » PowerEdge R430 R-Seriesby Dell. What if the Dell PowerEdge upgrade you're looking for isn't listed here? We're prepared for that too. Can't find the capacity you want for your PowerEdge R430 server or a specific memory module you need on our website? Please get in touch with your query. 16Gb (2X8Gb) Memory Ram Compatible with Dell Poweredge R430 Ddr4 EccR for Servers Only by CMS B7 $54.00 Dell PowerEdge R510 8 Bays 3.5 Server - 2X Intel Xeon L5640 2.26GHz 6 Core - 32GB DDR3 REG Memory - Dell H700 512MB Raid Controller - 4TB (2X 2TB SAS HDD) - 2X 750w PSU (Renewed). The Dell EMC PowerEdge R230 is an excellent first server or replacement server for driving applications in SMB. Compared to the previous-generation PowerEdge R220, the R230 delivers greater memory capacity, more hard drives and I/O slots, and accelerates data throughput and IOPs performance.
Dell R430 Dimm Slots
Poweredge R430 Memory Upgrade
Environmental specifications | |
---|---|
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. | |
Temperature | |
Storage | –40°C to 65°C (–40°F to 149°F) |
Continuous operation (for altitude less than 950 m or 3117 ft) | 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment. |
Fresh air | For information on fresh air, see Expanded Operating Temperature section. |
Maximum temperature gradient (operating and storage) | 20°C/h (36°F/h) |
Relative humidity | |
Storage | 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times. |
Operating | 10% to 80% Relative Humidity with 29°C (84.2°F) maximum dew point. |
Maximum vibration | |
Operating | 0.26 G rms at 5 Hz to 350 Hz (all operation orientations). |
Storage | 1.88 G rms at 10 Hz to 500 Hz for 15 min (all six sides tested). |
Maximum shock | |
Operating | Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 40 G for up to 2.3 ms. |
Storage | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. |
Maximum altitude | |
Operating | 3048 2000 m (10,000 6560 ft). |
Storage | 12,000 m (39,370 ft). |
Operating temperature de-rating | |
Up to 35 °C (95 °F) | Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). |
35 °C to 40 °C (95 °F to 104 °F) | Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). |
40 °C to 45 °C (104 °F to 113 °F) | Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). |
Particulate contamination NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer. | |
Air filtration NOTE: Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. | Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: Air entering the data center must have MERV11 or MERV13 filtration. |
Conductive dust NOTE: Applies to data center and non-data center environments. | Air must be free of conductive dust, zinc whiskers, or other conductive particles. |
Corrosive dust NOTE: Applies to data center and non-data center environments. |
|
Gaseous contamination | |
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity. | |
Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985. |
Silver coupon corrosion rate | <200 Å/month as defined by AHSRAE TC9.9. |